3.3.8.78 PDR79 : "A user terminated Copyback from <physical disk> to <physical disk>."
When event is generated, message will have the following substitutions:
<physical disk> = "Disk 5 in Enclosure 0 on Connector 0 of RAID Controller in Slot 5"
<physical disk> = " Disk 6 in Enclosure 0 on Coonnector 0 of RAID Controller in Slot 5"
3.3.8.79 PDR81 : "Microcode update started on <physical disk>."
When event is generated, message will have the following substitutions:
<physical disk> = "Disk 5 in Enclosure 0 on Connector 0 of RAID Controller in Slot 5"
3.3.8.80 PDR82 : "<physical disk> security was activated."
When event is generated, message will have the following substitutions:
<physical disk> = "Disk 5 in Enclosure 0 on Connector 0 of RAID Controller in Slot 5"
3.3.8.81 PDR83 : "<PD Name> is reprovisioned."
When event is generated, message will have the following substitutions:
<PD Name> = "Disk 5 in Enclosure 0 on Connector 0 of RAID Controller in Slot 5"
3.3.8.82 PDR84 : "<physical disk> Security key has changed."
When event is generated, message will have the following substitutions:
<physical disk> = "Disk 5 in Enclosure 0 on Connector 0 of RAID Controller in Slot 5"
3.3.8.83 PDR85 : "Security subsystem errors detected for <physical disk>."
When event is generated, message will have the following substitutions:
<physical disk> = "Disk 5 in Enclosure 0 on Connector 0 of RAID Controller in Slot 5"
3.3.8.84 PDR86 : "Bad block table on <physical disk> is full."
When event is generated, message will have the following substitutions:
<physical disk> = "Disk 5 in Enclosure 0 on Connector 0 of RAID Controller in Slot 5"
3.3.8.85 PDR87 : "<physical device> was reset."
When event is generated, message will have the following substitutions:
<physical device> = "Disk 5 in Enclosure 0 on Connector 0 of RAID Controller in Slot 5"
3.3.8.86 PDR88 : "Power state change failed on <PD Name>. (from <state> to <state>)"
When event is generated, message will have the following substitutions:
<PD Name> = "Disk 5 in Enclosure 0 on Connector 0 of RAID Controller in Slot 5"
<state> = "Spun Up"
<state> = "Spun Down"