2.4.25.11 PWR200 : "Enabling the Max Power Conservation Mode (MPCM) feature will
disable the Extended Power Performance (EPP) feature."
2.4.25.12 PWR201 : "Selecting the Server Based Power Management Mode option sets your
power cap to a maximum value, server priorities to a default priority, and then disables the
Max Power Conservation Mode. Do you want to continue?"
2.4.25.13 PWR202 : "Enabling the Max Power Conservation Mode (MPCM) feature forces
servers in to a low-power and limited-performance mode, and then disables the ability to
turn on additional servers."
2.4.25.14 PWR203 : "Unable to set the System Input Power Cap value to less than or equal to
13300 W (45381 BTU/h), because the Extended Power Performance feature is enabled."
2.4.25.15 PWR204 : "Object value is successfully modified. Max Power Conservation Mode
will deactivate the Extended Power Performance feature."
2.4.25.16 PWR205 : "The Server Performance Over Power Redundancy (SPOPR) feature
cannot be enabled because the Extended Power Performance is enabled."
2.4.25.17 PWR206 : "The Server Based Power Management (SBPM) feature cannot be
enabled because the Extended Power Performance mode is enabled."
2.4.25.18 PWR207 : "The Dynamic Power Supply Engagement (DPSE) feature cannot be
enabled because the Extended Power Performance mode is enabled."
2.4.25.19 PWR209 : "Unable to change the redundancy policy to either Power Supply
Redundancy or No Redundancy because the Extended Power Performance is enabled."
2.4.25.20 PWR210 : "The redundancy policy cannot be changed to either Power Supply
Redundancy or No Redundancy because the Extended Power Performance is enabled."
2.4.25.21 PWR211 : "Unable to set the Fresh Air (FA) mode because the Extended Power
Performance (EPP) feature is enabled."
2.4.25.22 PWR213 : "Cannot enable the Extended Power Performance (EPP) mode because
the Max Power Conservation Mode (MPCM) is enabled."
2.4.25.23 PWR214 : "Cannot enable the Extended Power Performance (EPP) mode because
Dynamic Power Supply Engagement (DPSE) is enabled."
2.4.25.24 PWR216 : "Unable to enable Extended Power Performance, because Redundancy
Policy is set to Grid Redundancy or No Redundancy."
2.4.25.25 PWR218 : "Cannot enable the Extended Power Performance (EPP) feature because
the Fresh Air (FA) mode is enabled."
2.4.25.26 PWR219 : "The Extended Power Performance (EPP) feature cannot be enabled
because the PSU in slot <slot number> is not a 3000 W PSU."
When event is generated, message will have the following substitutions: